MODEL | MIG-270K | MIG-350K | ||||
Nominal kirish kuchlanishi (V) | 1P 220V | 3P 220V | 3P 380V | 1P 220V | 3P 220V | 3P 380V |
Chastotasi(Hz) | 50/60 | 50/60 | ||||
Maksimal kirish oqimi (A) | 27 | 14 | 16 | 39 | 20 | 23 |
Nominal kirish quvvati (KVA) | 5.3 | 10.3 | 7.6 | 15.3 | ||
Yuksiz kuchlanish (V) | 54 | 62 | ||||
Sozlash joriy diapazoni(A) | 40-170 | 40-250 | 40-220 | 40-350 | ||
Nominal ish kuchlanishi (V) | 23 | 27.5 | 25 | 31.5 | ||
Ish aylanishi (%) | 60 | 60 | ||||
MMA funktsiyasi | HA | HA | ||||
Tel oziqlantiruvchi | o'rnatilgan | |||||
Sim diametri (MM) | 0,8-1,0 | 0,8-1,0 | 0,8-1,0 | 0,8-1,0 | 0,8-1,0 | 0,8-1,2 |
Himoya tasnifi | IP21 S | IP21S | ||||
Sof vazn (KG) | 30 | 32 | ||||
Mashina o'lchamlari (MM) | 660x280x555 | 660x280x555 |
● IGBT inverteri avtomatik suv ostida payvandlash mashinasi
1) O'rnatish joyi payvandchini qo'llab-quvvatlash uchun etarlicha mustahkam bo'lishi kerak.
2) Payvandlovchini suv sachrashi mumkin bo'lgan joylarga, masalan, suv quvurlariga o'rnatish taqiqlanadi.3) Payvandlash ishlari havo namligi odatda 90% dan yuqori bo'lmagan nisbatan quruq muhitda amalga oshirilishi kerak.
4) Atrof-muhit harorati -10 ° C dan + 40 ° C gacha bo'lishi kerak.
5) Chang yoki korroziy gaz o'z ichiga olgan joylarda payvandlash ishlarini bajarmang.
6) Payvandlovchini 15° dan kattaroq moyillikdagi stol usti ustiga qo'ymang.
Payvandchi haddan tashqari kuchlanish, haddan tashqari oqim va qizib ketishdan himoya zanjirlari bilan o'rnatildi.Tarmoq kuchlanishi, chiqish oqimi va ichki harorat belgilangan standartlardan oshib ketganda, payvandchi avtomatik ravishda ishlashni to'xtatadi, lekin ortiqcha foydalanish (masalan, haddan tashqari kuchlanish) payvandchiga zarar etkazishi mumkin, shuning uchun quyidagi masalalarga e'tibor berish kerak:
● Haddan tashqari kuchlanishni taqiqlang
Umuman olganda, payvandchi ichidagi avtomatik kuchlanish kompensatsiyasi sxemasi payvandlash oqimining ruxsat etilgan diapazonda saqlanishini ta'minlaydi.Agar ta'minot kuchlanishi ruxsat etilgan qiymatdan oshib ketsa, u payvandchiga zarar etkazadi.
● Haddan tashqari yuklashni taqiqlang
Operatorlar payvandchini ruxsat etilgan yuklanish muddati darajasiga ko'ra ishlatishlari va payvandlash oqimini maksimal ruxsat etilgan yuk oqimida saqlashlari kerak.Hozirgi ortiqcha yuk payvandchining ishlash muddatini sezilarli darajada qisqartiradi yoki hatto uni yoqib yuboradi.
Agar payvandchi ishlayotganda standart yuklanish muddatidan oshib ketsa, u to'satdan himoya holatiga tushib, ishlamay qolishi mumkin.Bu shuni ko'rsatadiki, standart yuklanish muddati o'tib ketgandan so'ng, payvandchini to'xtatish uchun haroratni boshqarish tugmachasini ishga tushirish uchun qiziydi va old paneldagi sariq indikator bir vaqtning o'zida yonadi.Bunday holda, elektr vilkasini tortib olmang.Ventilyator payvandchini sovutib qo'ying. Sariq indikator o'chganida va harorat standart diapazonga tushganda, payvandlashni boshlang.